The RDBA-15 continuously measures oil content in the sample stream from a ship’s bilge water separator. The display shows the reading in ppm. If the oil concentration exceeds 15 ppm, the unit gives audible and visual alarms and provides a relay output for discharge control.

Technical Specifications
| Oil content measuring range | 0–30 ppm |
|---|---|
| Alarm set point | 15 ppm |
| Resolution / display accuracy | 0.1 ppm / ±5 ppm |
| Response time | ≤5 seconds |
| Alarm delay | 0–99 seconds, adjustable |
| Sample pressure | 0.02–0.5 MPa |
| Alarm signal | Audible and visual |
| Alarm relay contact rating | 5 A at 250 V |
| Power supply | 220 V AC |
| Enclosure protection | IP44 |
| Ambient temperature | 0 to +55 °C |
Selecting a replacement bilge alarm
Send the separator make and model, sample line pressure, supply voltage and relay wiring requirements. For a replacement, include the existing alarm nameplate.
Contact Right Marine · Oil discharge monitoring system for tankers